86exporter.com Home       Products Catalog      Suppliers Catalog      Log In        Sign up
      About Us
      Profile
      Products
      Contact Us


Xiamen Ecosafene Product Technical Service Co.,Ltd

Products >> 16 CFR 1633 Flammability Test To Mattresses

16 CFR 1633 Flammability Test To Mattresses

Build Your Online Product Catalogs?



Description
Product Name: 16 CFR 1633 Flammability Test To Mattresses
Supply Ability:
Related proudcts flammability test, mattresses, 16 cfr 1633,
Specifications 16 CFR 1633
Price Term:
Port of loading:
Minimum Order
Unit Price:

16 CFR 1633 Flammability Test(Open Flame) to Mattresses and Mattress/ Foundation Sets


Ecosafene have rich experience to provide 16 CFR 1633 Flammability Test(Open Flame) to Mattresses and Mattress/ Foundation Sets.

16 CFR 1633 Flammability Test to Mattresses and Mattress/ Foundation Sets�Standard

16 CFR Part 1633 Standard for the Flammability (Open Flame) of Mattresses and Mattress/ Foundation Sets

16 CFR 1633 Flammability Test to Mattresses and Mattress/ Foundation Sets�Purpose

This part 1633 establishes flammability requirements that all mattress sets must meet before sale or introduction into commerce. The purpose of the standard is to reduce deaths and injuries associated with mattress fires by limiting the size of the fire generated by a mattress set during a thirty minute test.

16 CFR 1633 Flammability Test to Mattresses and Mattress/ Foundation Sets�Summary of test method

The test method set forth in § 1633.7 measures the flammability (fire test response characteristics) of a mattress specimen by exposing the specimen to a specified
flaming ignition source and allowing it to burn freely under well-ventilated,controlled environmental conditions.The flaming ignition source shall be a pair of propane burners. These burners impose differing fluxes for differing times on the top and sides of the specimen.During and after this exposure,measurements shall be made of the time-dependent heat release rate from the specimen, quantifying the energy generated by the fire. The rate of heat release must be measured by means of oxygen consumption calorimetry.

16 CFR 1633 Flammability Test to Mattresses and Mattress/ Foundation Sets–Technical requirements

(i) The peak rate of heat release shall not exceed 200 kilowatts ("kW") at any time within the 30 minute test;

(ii) The total heat release shall not exceed 15 megajoules ("MJ") for the first 10 minutes of the test.

16 CFR 1633 Flammability Test to Mattresses and Mattress/ Foundation Sets - Relative Standard

16 CFR PART 163

Contact Us
Company: Xiamen Ecosafene Product Technical Service Co.,Ltd
Contact: Ms. Anne Lin
Address: 1812 Gangmao Mansion, No.22 Xingqian Road, Jimei,Xiamen 361022, China
Postcode:
Tel: 86-0592-5056211
Fax: 86-0592-5105807
E-mail:         


Copyright© Xiamen Ecosafene Product Technical Service Co.,Ltd All Rights Reserved.
Tel : 86-0592-5056211 Fax : 86-0592-5105807
Powered by 86exporter.com